RT2005, thermal resistances

What are the thermal resistance values ​​recommended by RT2005 for the different walls and places to be insulated in a new house?

These values ​​are taken from the following document:
Insulation: thermal resistance recommended by RT2005 and concern a dwelling placed in H1 climatic zone (the coldest).

Lost attics: Recommended resistance> = 6.5.

Converted attic isolated from the inside: Recommended resistance 6.0 to 6.5.

Converted attic isolated from the outside: Recommended resistance 5.5.

walls: Recommended resistance 2.85 to 3.15.

Floors on unheated premises: Recommended resistance> = 3.15.

Floors on crawl spaces: Recommended resistance of 2.40 to 3.50.

Floors on land-full: Recommended resistance of 2.40 to 2.75.

Roof terrace on concrete slab: Recommended resistance> = 3.45.